You are here: irt.org | RFCs | RFC4327 [ previous next ]
Network Working Group M. Dubuc Request for Comments: 4327 T. Nadeau Category: Standards Track Cisco Systems J. Lang Sonos, Inc. E. McGinnis Hammerhead Systems January 2006 Link Management Protocol (LMP) Management Information Base (MIB) Status of This Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (2006). Abstract This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes managed objects for modeling the Link Management Protocol (LMP). Table of Contents 1. The Internet-Standard Management Framework ......................2 2. Introduction ....................................................2 3. Terminology .....................................................3 4. Feature Checklist ...............................................3 5. Outline .........................................................4 6. Brief Description of MIB Objects ................................4 6.1. lmpNbrTable ................................................4 6.2. lmpControlChannelTable .....................................4 6.3. lmpControlChannelPerfTable .................................4 6.4. lmpTeLinkTable .............................................5 6.5. lmpLinkVerificationTable ...................................5 6.6. lmpTeLinkPerfTable .........................................5 6.7. lmpDataLinkTable ...........................................5 6.8. lmpDataLinkPerfTable .......................................5 7. Example of LMP Control Channel Setup ............................5 Dubuc, et al. Standards Track [Page 1]
RFC 4327 LMP-MIB Module January 2006 8. Application of the Interfaces Group to LMP ......................8 8.1. Support of the LMP Layer by ifTable ........................9 9. LMP MIB Module Definitions .....................................11 10. Security Considerations .......................................77 11. Contributors ..................................................78 12. Acknowledgements ..............................................78 13. IANA Considerations ...........................................78 13.1. IANA Considerations for lmp ifType .......................78 13.2. IANA Considerations for LMP-MIB ..........................78 14. References ....................................................79 14.1. Normative References .....................................79 14.2. Informative References ...................................80 1. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580]. 2. Introduction Current work is under way in the IETF to specify a suite of protocols to be used as a common control plane and a separate common measurement plane. Generalized MPLS (GMPLS) [RFC3471] and the Link Management Protocol [RFC4204] are key components of this standardization activity. The primary purpose of LMP is to manage traffic engineering (TE) links. Primary goals of LMP are the maintenance of the control channel connectivity, correlation of link properties, verification of data-bearing links, and detection and isolation of link faults. We describe in this document a MIB module that can be used to manage LMP implementations. This MIB module covers both configuration and performance monitoring aspects of LMP. The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [RFC2119]. Dubuc, et al. Standards Track [Page 2]
RFC 4327 LMP-MIB Module January 2006 3. Terminology This document uses terminology from the document describing the Link Management Protocol [RFC4204]. An "LMP adjacency" is formed between two nodes that support the same capabilities, and LMP messages are exchanged between the node pair over control channels that form this adjacency. Several control channels can be active at the same time. With the exception of messages related to control channel management, anytime an LMP message needs to be transferred to a neighbor node, it can be sent on any of the active control channels. The control channels can also be used to exchange MPLS control plane information or routing information. LMP is designed to support aggregation of one or more data-bearing links into a traffic-engineering (TE) link. The data-bearing links can be either component links or ports depending on their multiplexing capability (see [RFC4204] for distinction between port and component link). Each TE link is associated with an LMP adjacency, and one or more control channels are used to exchange LMP messages for a particular adjacency. In turn, control channels are used to manage the TE links associated with the LMP adjacency. 4. Feature Checklist The Link Management Protocol MIB module (LMP-MIB) is designed to satisfy the following requirements and constraints: - The MIB module supports the enabling and disabling of LMP capability on LMP-capable interfaces of a photonic switch, optical cross-connect, or router. - The MIB module is used to provide information about LMP adjacencies. - Support is provided for configuration of the keep alive and link verification parameters. - The MIB module is used to express the mapping between local and remote TE links, as well as local and remote interface identifiers for port or component link. - Performance counters are provided for measuring LMP performance on a per-control channel basis. Performance counters are also provided for measuring LMP performance on the data-bearing links. Dubuc, et al. Standards Track [Page 3]
RFC 4327 LMP-MIB Module January 2006 Note that the LMP MIB module goes hand-in-hand with the TE Link (TE-LINK-STD-MIB) MIB module [RFC4220]. The TE link table, which is used to associate data-bearing links to TE links, is defined in the TE Link MIB. The TE link table in the LMP MIB module contains TE link information specific to LMP. 5. Outline Configuring LMP through an optical device involves the following steps: - Enabling LMP on LMP-capable interfaces through control channel configuration. - Optionally specifying link verification parameters. - Configuring the data-bearing links and associating them to the appropriate TE link (this association is stored in the ifStackTable of the Interfaces Group MIB). TE links are managed by the control channels that run between the same pair of nodes (LMP adjacency). 6. Brief Description of MIB Objects Sections 6.1-6.8 describe objects pertaining to LMP. The MIB objects were derived from the LMP document [RFC4204]. 6.1. lmpNbrTable The remote node table is used to identify the pair of nodes that exchange LMP messages over control channels. 6.2. lmpControlChannelTable The control channel table is used for enabling the LMP protocol on LMP-capable interfaces. A photonic switch, optical cross-connect, or router creates an entry in this table for every LMP-capable interface in that device. 6.3. lmpControlChannelPerfTable The control channel performance table is used for collecting LMP performance counts on a per-control channel basis. Each entry in the lmpControlChannelTable has a corresponding entry in the lmpControlChannelPerfTable. Dubuc, et al. Standards Track [Page 4]
RFC 4327 LMP-MIB Module January 2006 6.4. lmpTeLinkTable The TE link table is used for specifying LMP information associated with TE links. 6.5. lmpLinkVerificationTable The link verification table is used for configuring the LMP link verification parameters of TE links. For every TE link entry in the lmpTeLinkTable that supports the link verification procedure, there is a corresponding entry in the lmpLinkVerificationTable. 6.6. lmpTeLinkPerfTable The TE link performance table is used for collecting LMP performance counts on a per-TE link basis. Each entry in the lmpTeLinkTable has a corresponding entry in the lmpTeLinkPerfTable. 6.7. lmpDataLinkTable The data-bearing link table is used to specify the data-bearing links that are associated with TE links. 6.8. lmpDataLinkPerfTable The data-bearing link performance table is used for collecting LMP performance counts on data-bearing links. 7. Example of LMP Control Channel Setup In this section, we provide a brief example of using the MIB objects described in section 9 to set up an LMP control channel. While this example is not meant to illustrate every nuance of the MIB module, it is intended as an aid to understanding some of the key concepts. It is meant to be read after going through the MIB itself. Suppose that one would like to form an LMP adjacency between two nodes using two control channels. Suppose also that there are three data-bearing links. We also assume that the data-bearing links are ports (lambdas). We also assume that the link verification procedure is not enabled. The following example illustrates which rows and corresponding objects might be created to accomplish this. First, LMP must be enabled between the pair of nodes. Dubuc, et al. Standards Track [Page 5]
RFC 4327 LMP-MIB Module January 2006 In lmpNbrTable: { lmpNbrNodeId = 'c0000201'H, -- 192.0.2.1 lmpNbrAdminStatus = up(1), lmpNbrRowStatus = createAndGo(4), lmpNbrStorageType = nonVolatile(3) } Then, the control channels must be set up. These are created in the lmpControlChannelTable. In lmpControlChannelTable: { lmpCcId = 1, lmpCcUnderlyingIfIndex = 1, lmpCcIsIf = false(1), lmpCcAuthentication = false(1), lmpCcHelloInterval = 15, lmpCcHelloIntervalMin = 15, lmpCcHelloIntervalMax = 1000, lmpCcHelloDeadInterval = 45, lmpCcHelloDeadIntervalMin = 45, lmpCcHelloDeadIntervalMax = 1000, lmpCcAdminStatus = up(1), lmpCcRowStatus = createAndGo(4), lmpCcStorageType = nonVolatile(3) } { lmpCcId = 2, lmpCcUnderlyingIfIndex = 2, lmpCcIsIf = false(1), lmpCcAuthentication = false(1), lmpCcHelloInterval = 15, lmpCcHelloIntervalMin = 15, lmpCcHelloIntervalMax = 1000, lmpCcHelloDeadInterval = 45, lmpCcHelloDeadIntervalMin = 45, lmpCcHelloDeadIntervalMax = 1000, lmpCcAdminStatus = up(1), lmpCcRowStatus = createAndGo(4), lmpCcStorageType = nonVolatile(3) } Next, the three data-bearing links are created. For each data- bearing link, an ifEntry with the same ifIndex needs to be created beforehand. Dubuc, et al. Standards Track [Page 6]
RFC 4327 LMP-MIB Module January 2006 In lmpDataLinkTable: { ifIndex = 41, lmpDataLinkAddressType = unknown(0), lmpDataLinkIpAddr = ''H, lmpDataLinkRemoteIpAddress = ''H, lmpDataLinkRemoteIfId = 47, lmpDataLinkRowStatus = createAndGo(4), lmpDataLinkStorageType = nonVolatile(3) } { ifIndex = 43, lmpDataLinkAddressType = unknown(0), lmpDataLinkIpAddr = ''H, lmpDataLinkRemoteIpAddress = ''H, lmpDataLinkRemoteIfId = 42, lmpDataLinkRowStatus = createAndGo(4), lmpDataLinkStorageType = nonVolatile(3) } { ifIndex = 44, lmpDataLinkAddressType = unknown(0), lmpDataLinkIpAddr = ''H, lmpDataLinkRemoteIpAddress = ''H, lmpDataLinkRemoteIfId = 48, lmpDataLinkRowStatus = createAndGo(4), lmpDataLinkStorageType = nonVolatile(3) } Note that the data-bearing link type (lmpDataLinkType) does not need to be provisioned as it is automatically populated by the node. The definition of the protection role (primary or secondary) for the data-bearing links is stored in the componentLinkTable of the TE Link MIB module [RFC4220]. Then, a TE link is created as an ifEntry with ifType teLink in the ifTable. Once the TE link is created in the ifTable, a TE link entry is created in the LMP MIB module to specify TE link information specific to LMP. In lmpTeLinkTable: { ifIndex = 20, lmpTeLinkVerification = true(2), Dubuc, et al. Standards Track [Page 7]
RFC 4327 LMP-MIB Module January 2006 lmpTeLinkFaultManagement = true(2), lmpTeLinkDwdm = false(1), lmpTeLinkRowStatus = createAndGo(4), lmpTeLinkStorageType = nonVolatile(3) } and in lmpLinkVerificationTable: { ifIndex = 20, lmpLinkVerifyInterval = 100, lmpLinkVerifyDeadInterval = 300, lmpLinkVerifyTransportMechanism = j0Trace(3), lmpLinkVerifyAllLinks = true(2), lmpLinkVerifyTransmissionRate = 100000, lmpLinkVerifyWavelength = 0, lmpLinkVerifyRowStatus = createAndGo(4), lmpLinkVerifyStorageType = nonVolatile(3) } The association between the data-bearing links and the TE links is stored in the ifStackTable [RFC2863]. In parallel with the entry created in the lmpTeLinkTable, an entry may be created in the teLinkTable of TE Link MIB module [RFC4220]. 8. Application of the Interfaces Group to LMP The Interfaces Group [RFC2863] defines generic managed objects for managing interfaces. This memo contains the media-specific extensions to the Interfaces Group for managing LMP control channels that are modeled as interfaces. If the control channel as defined in the lmpControlChannelTable is modeled as an ifEntry, then the following definition applies. An lmpControlChannelTable entry is designated as being represented as an Interfaces MIB ifEntry if the lmpControlChannelEntry object lmpCcIsIf is set to true (2). In this case, the control channel SHOULD be modeled as an ifEntry and provide appropriate interface stacking as defined below. This memo assumes the interpretation of the Interfaces Group to be in accordance with [RFC2863], which states that the interfaces table (ifTable) contains information on the managed resource's interfaces and that each sub-layer below the internetwork layer of a network interface is considered an interface. Since the LMP interface only carries control traffic, it is considered to be below the internetwork layer. Thus, the LMP interface may be represented as an entry in the ifTable. The interrelation of entries in the ifTable is defined by Interfaces Stack Group defined in [RFC2863]. Dubuc, et al. Standards Track [Page 8]
RFC 4327 LMP-MIB Module January 2006 When LMP control channels are modeled as interfaces, the interface stack table must appear as follows for the LMP control channel interfaces: +----------------------------------------+ | LMP-interface ifType = lmp(227) + +----------------------------------------+ | Underlying Layer... + +----------------------------------------+ In the above diagram, "Underlying Layer..." refers to the ifIndex of any interface type over which the LMP interface will transmit its traffic. Note that if the underlying layer provides multiple access to its media (i.e., Ethernet), then it is possible to stack multiple LMP interfaces on top of this interface in parallel. Note that it is not a requirement that LMP control channels be modeled as interfaces. It is acceptable that control channels simply exist as logical connections between adjacent LMP-capable nodes. In this case, lmpCcIsIf is set to false(2) and no corresponding entry is made in the ifTable. 8.1. Support of the LMP Layer by ifTable Some specific interpretations of ifTable for the LMP layer follow. Object Use for the LMP layer. ifIndex Each LMP interface may be represented by an ifEntry. ifDescr Description of the LMP interface. ifType The value that is allocated for LMP is 227. This number has been assigned by the IANA. ifSpeed The total bandwidth in bits per second for use by the LMP layer. ifPhysAddress Unused. ifAdminStatus This variable indicates the administrator's intent as to whether LMP should be enabled, disabled, or running in some diagnostic testing mode on this interface. Also see [RFC2863]. ifOperStatus This value reflects the actual or operational status of LMP on this interface. Dubuc, et al. Standards Track [Page 9]
RFC 4327 LMP-MIB Module January 2006 ifLastChange See [RFC2863]. ifInOctets The number of received octets over the interface, i.e., the number of octets received as LMP packets. ifOutOctets The number of transmitted octets over the interface, i.e., the number of octets transmitted as LMP packets. ifInErrors The number of LMP packets dropped due to uncorrectable errors. ifInUnknownProtos The number of received packets discarded during packet header validation, including packets with unrecognized label values. ifOutErrors See [RFC2863]. ifName Textual name (unique on this system) of the interface or an octet string of zero length. ifLinkUpDownTrapEnable Default is disabled (2). ifConnectorPresent Set to false (2). ifHighSpeed See [RFC2863]. ifHCInOctets The 64-bit version of ifInOctets; supported if required by the compliance statements in [RFC2863]. ifHCOutOctets The 64-bit version of ifOutOctets; supported if required by the compliance statements in [RFC2863]. ifAlias The nonvolatile 'alias' name for the interface as specified by a network manager. ifCounterDiscontinuityTime See [RFC2863]. Dubuc, et al. Standards Track [Page 10]
RFC 4327 LMP-MIB Module January 2006 9. LMP MIB Module Definitions This MIB module IMPORTs objects from [RFC2578], [RFC2579], [RFC2580], [RFC2863], [RFC4001], and [RFC4220], and it has REFERENCE clauses to [RFC4204], [RFC4207], [RFC4209], [RFC3471], and [RFC2914]. LMP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, transmission, Unsigned32, Counter32, TimeTicks FROM SNMPv2-SMI -- [RFC2578] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] TEXTUAL-CONVENTION, TruthValue, RowStatus, StorageType, TimeStamp FROM SNMPv2-TC -- [RFC2579] InterfaceIndexOrZero, ifIndex FROM IF-MIB -- [RFC2863] InetAddressType, InetAddress FROM INET-ADDRESS-MIB -- [RFC4001] teLinkRemoteIpAddr, teLinkIncomingIfId, TeLinkEncodingType FROM TE-LINK-STD-MIB; -- [RFC4220] lmpMIB MODULE-IDENTITY LAST-UPDATED "200601110000Z" -- 11 January 2006 ORGANIZATION "Common Control and Measurement Protocols (CCAMP) Working Group" CONTACT-INFO " Martin Dubuc Email: dubuc.consulting@sympatico.ca Thomas D. Nadeau Email: tnadeau@cisco.com Jonathan P. Lang Email: jplang@ieee.org Evan McGinnis Email: emcginnis@hammerheadsystems.com" DESCRIPTION Dubuc, et al. Standards Track [Page 11]
RFC 4327 LMP-MIB Module January 2006 "Copyright (C) 2006 The Internet Society. This version of the MIB module is part of RFC 4327; see the RFC itself for full legal notices. This MIB module contains managed object definitions for the Link Management Protocol (LMP) as defined in 'Link Management Protocol'." -- Revision history. REVISION "200601110000Z" -- 11 January 2006 DESCRIPTION "Initial version published as RFC 4327" ::= { transmission 227 } -- Textual Conventions LmpInterval ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The interval delay in milliseconds." SYNTAX Unsigned32 (1..65535) LmpRetransmitInterval ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The retransmission interval delay in milliseconds." SYNTAX Unsigned32 (1..4294967295) LmpNodeId ::= TEXTUAL-CONVENTION DISPLAY-HINT "1d.1d.1d.1d" STATUS current DESCRIPTION "Represents a Node ID in network byte order. Node ID is an address of type IPv4." REFERENCE "Section 1.1 of Link Management Protocol, RFC 4204" SYNTAX OCTET STRING(SIZE(4)) -- Top level components of this MIB -- Notifications lmpNotifications OBJECT IDENTIFIER ::= { lmpMIB 0 } -- Tables, Scalars lmpObjects OBJECT IDENTIFIER ::= { lmpMIB 1 } Dubuc, et al. Standards Track [Page 12]
RFC 4327 LMP-MIB Module January 2006 -- Conformance lmpConformance OBJECT IDENTIFIER ::= { lmpMIB 2 } lmpAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired operational status of LMP on the node. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." DEFVAL { up } ::= { lmpObjects 1 } lmpOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of LMP on the node." ::= { lmpObjects 2 } -- LMP Neighbor Table lmpNbrTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpNbrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the neighbor node(s) to which control channels may be established." ::= { lmpObjects 3 } lmpNbrEntry OBJECT-TYPE SYNTAX LmpNbrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by a LMP-enabled device for every pair of nodes that can establish control channels." INDEX { lmpNbrNodeId } ::= { lmpNbrTable 1 } LmpNbrEntry ::= SEQUENCE { lmpNbrNodeId LmpNodeId, lmpNbrRetransmitInterval LmpRetransmitInterval, Dubuc, et al. Standards Track [Page 13]
RFC 4327 LMP-MIB Module January 2006 lmpNbrRetryLimit Unsigned32, lmpNbrRetransmitDelta Unsigned32, lmpNbrAdminStatus INTEGER, lmpNbrOperStatus INTEGER, lmpNbrRowStatus RowStatus, lmpNbrStorageType StorageType } lmpNbrNodeId OBJECT-TYPE SYNTAX LmpNodeId MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the LmpNbrTable. This value represents the remote Node ID." ::= { lmpNbrEntry 1 } lmpNbrRetransmitInterval OBJECT-TYPE SYNTAX LmpRetransmitInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the initial retransmission interval that is used for the retransmission of messages that require acknowledgement. This object along with lmpNbrRetryLimit is used to implement congestion-handling mechanism as defined in Section 10 of the Link Management Protocol specification, which is based on RFC 2914." REFERENCE "Link Management Protocol, RFC 4204. Congestion Control Principles, RFC 2914." DEFVAL { 500 } ::= { lmpNbrEntry 2 } lmpNbrRetryLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the maximum number of times a message is transmitted without being acknowledged. A value of 0 is used to indicate that a node should never stop retransmission. This object along with lmpNbrRetransmitInterval is used to implement congestion-handling mechanism as defined in Section 10 of the Link Management Protocol specification, which is based on RFC 2914." REFERENCE Dubuc, et al. Standards Track [Page 14]
RFC 4327 LMP-MIB Module January 2006 "Link Management Protocol, RFC 4204. Congestion Control Principles, RFC 2914." DEFVAL { 3 } ::= { lmpNbrEntry 3 } lmpNbrRetransmitDelta OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object governs the speed with which the sender increases the retransmission interval as explained in section 10 of the Link Management Protocol specification, which is based on RFC 2914. This value is a power used to express the exponential backoff. The ratio of two successive retransmission intervals is (1 + Delta)." REFERENCE "Link Management Protocol, RFC 4204. Congestion Control Principles, RFC 2914." DEFVAL { 1 } ::= { lmpNbrEntry 4 } lmpNbrAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The desired operational status of LMP to this remote node." ::= { lmpNbrEntry 5 } lmpNbrOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of LMP to this remote node." ::= { lmpNbrEntry 6 } lmpNbrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). Dubuc, et al. Standards Track [Page 15]
RFC 4327 LMP-MIB Module January 2006 All read-create objects must have valid and consistent values before the row can be activated." ::= { lmpNbrEntry 7 } lmpNbrStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row in the lmpNbrTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row." DEFVAL { nonVolatile } ::= { lmpNbrEntry 8 } -- End of lmpNbrTable lmpCcHelloIntervalDefault OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default value for the HelloInterval parameter used in the Hello protocol keep-alive phase. It indicates how frequently LMP Hello messages will be sent. It is used a the default value for lmpCcHelloInterval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpObjects 4 } lmpCcHelloIntervalDefaultMin OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default minimum value for the HelloInterval parameter. It is used as a default value for lmpCcHelloIntervalMin. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." ::= { lmpObjects 5 } lmpCcHelloIntervalDefaultMax OBJECT-TYPE SYNTAX LmpInterval Dubuc, et al. Standards Track [Page 16]
RFC 4327 LMP-MIB Module January 2006 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default maximum value for the HelloInterval parameter. It is used as a default value for lmpCcHelloIntervalMax. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." ::= { lmpObjects 6 } lmpCcHelloDeadIntervalDefault OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default HelloDeadInterval parameter to use in the Hello protocol keep-alive phase. It indicates how long a device should wait before declaring the control channel dead. The HelloDeadInterval parameter should be at least three times the value of HelloInterval. It is used as a default value for lmpCcHelloDeadInterval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpObjects 7 } lmpCcHelloDeadIntervalDefaultMin OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default minimum value for the HelloDeadInterval parameter. It is used as a default value for lmpCcHelloDeadIntervalMin. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." ::= { lmpObjects 8 } lmpCcHelloDeadIntervalDefaultMax OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default maximum value for the HelloDeadInterval parameter. It is used as a default value for lmpCcHelloDeadIntervalMax. Implementations should save the value of this object in persistent memory so that it survives Dubuc, et al. Standards Track [Page 17]
RFC 4327 LMP-MIB Module January 2006 restarts or reboot." ::= { lmpObjects 9 } -- LMP Control Channel Table lmpControlChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpControlChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies LMP control channel information." ::= { lmpObjects 10 } lmpControlChannelEntry OBJECT-TYPE SYNTAX LmpControlChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by a LMP-enabled device for every control channel. Whenever a new entry is created with lmpCcIsIf set to true(2), then a corresponding entry is created in ifTable as well (see RFC 2863)." INDEX { lmpCcId } ::= { lmpControlChannelTable 1 } LmpControlChannelEntry ::= SEQUENCE { lmpCcId Unsigned32, lmpCcUnderlyingIfIndex InterfaceIndexOrZero, lmpCcIsIf TruthValue, lmpCcNbrNodeId LmpNodeId, lmpCcRemoteId Unsigned32, lmpCcRemoteAddressType InetAddressType, lmpCcRemoteIpAddr InetAddress, lmpCcSetupRole INTEGER, lmpCcAuthentication TruthValue, lmpCcHelloInterval LmpInterval, lmpCcHelloIntervalMin LmpInterval, lmpCcHelloIntervalMax LmpInterval, lmpCcHelloIntervalNegotiated LmpInterval, lmpCcHelloDeadInterval LmpInterval, lmpCcHelloDeadIntervalMin LmpInterval, lmpCcHelloDeadIntervalMax LmpInterval, lmpCcHelloDeadIntervalNegotiated LmpInterval, lmpCcLastChange TimeTicks, lmpCcAdminStatus INTEGER, lmpCcOperStatus INTEGER, lmpCcRowStatus RowStatus, Dubuc, et al. Standards Track [Page 18]
RFC 4327 LMP-MIB Module January 2006 lmpCcStorageType StorageType } lmpCcId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value represents the local control channel identifier. The control channel identifier is a non-zero 32-bit number." ::= { lmpControlChannelEntry 1 } lmpCcUnderlyingIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "If lmpCcIsIf is set to true(1), this object carries the index into the ifTable of the entry that represents the LMP interface over which LMP will transmit its traffic. If this object is set to zero, but lmpCcIsIf is set to true(1), the control channel is not currently associated with any underlying interface and the control channel's operational status must not be up(1), nor should the control channel forward or receive traffic. If lmpCcIsIf is set to false(2), this object should be set to zero and should be ignored." ::= { lmpControlChannelEntry 2 } lmpCcIsIf OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "In implementations where the control channels are modeled as interfaces, the value of this object is true(1) and this control channel is represented by an interface in the interfaces group table as indicated by the value of lmpCcUnderlyingIfIndex. If control channels are not modeled as interfaces, the value of this object is false(2) and there is no corresponding interface for this control channel in the interfaces group table, and the value of lmpCcUnderlyingIfIndex should be ignored." ::= { lmpControlChannelEntry 3 } lmpCcNbrNodeId OBJECT-TYPE SYNTAX LmpNodeId Dubuc, et al. Standards Track [Page 19]
RFC 4327 LMP-MIB Module January 2006 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the Node ID of the control channel remote node. This value either is configured or gets created by the node when a Config message is received or when an outgoing Config message is acknowledged by the remote node." ::= { lmpControlChannelEntry 4 } lmpCcRemoteId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value represents the remote control channel identifier (32-bit number). It is determined during the negotiation phase. A value of zero means that the remote control channel identifier has not yet been learnt." ::= { lmpControlChannelEntry 5 } lmpCcRemoteAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "This value represents the remote control channel IP address type. In point-to-point configuration, this value can be set to unknown(0)." ::= { lmpControlChannelEntry 6 } lmpCcRemoteIpAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This value represents the remote control channel Internet address for numbered control channel. The type of this address is determined by lmpCcRemoteAddressType. Control channel must be numbered on non-point-to-point configuration. For point-to-point configuration, the remote control channel address can be of type unknown in which case this object must be a zero-length string. The lmpCcRemoteId object then identifies the unnumbered address." ::= { lmpControlChannelEntry 7 } lmpCcSetupRole OBJECT-TYPE SYNTAX INTEGER { active(1), passive(2) } Dubuc, et al. Standards Track [Page 20]
RFC 4327 LMP-MIB Module January 2006 MAX-ACCESS read-create STATUS current DESCRIPTION "The role that this node should take during establishment of this control channel. An active node will initiate establishment. A passive node will wait for the remote node to initiate. A pair of nodes that both take the passive role will never establish communications." DEFVAL { active } ::= { lmpControlChannelEntry 8 } lmpCcAuthentication OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates whether the control channel must use authentication." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpControlChannelEntry 9 } lmpCcHelloInterval OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the value of the HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalDefault." ::= { lmpControlChannelEntry 10 } lmpCcHelloIntervalMin OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the minimum value for the HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMinDefault." ::= { lmpControlChannelEntry 11 } lmpCcHelloIntervalMax OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the maximum value for the Dubuc, et al. Standards Track [Page 21]
RFC 4327 LMP-MIB Module January 2006 HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMaxDefault." ::= { lmpControlChannelEntry 12 } lmpCcHelloIntervalNegotiated OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-only STATUS current DESCRIPTION "Once the control channel is active, this object represents the negotiated HelloInterval value." ::= { lmpControlChannelEntry 13 } lmpCcHelloDeadInterval OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the value of the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloDeadIntervalDefault." ::= { lmpControlChannelEntry 14 } lmpCcHelloDeadIntervalMin OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the minimum value for the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloDeadIntervalMinDefault." ::= { lmpControlChannelEntry 15 } lmpCcHelloDeadIntervalMax OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the maximum value for the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMaxDefault." ::= { lmpControlChannelEntry 16 } lmpCcHelloDeadIntervalNegotiated OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-only STATUS current DESCRIPTION Dubuc, et al. Standards Track [Page 22]
RFC 4327 LMP-MIB Module January 2006 "Once the control channel is active, this object represents the negotiated HelloDeadInterval value." ::= { lmpControlChannelEntry 17 } lmpCcLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the control channel entered its current operational state. If the current state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { lmpControlChannelEntry 18 } lmpCcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The desired operational status of this control channel." ::= { lmpControlChannelEntry 19 } lmpCcOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), configSnd(3), configRcv(4), active(5), goingDown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of this control channel." ::= { lmpControlChannelEntry 20 } lmpCcRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent Dubuc, et al. Standards Track [Page 23]
RFC 4327 LMP-MIB Module January 2006 values before the row can be activated." ::= { lmpControlChannelEntry 21 } lmpCcStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row in the lmpControlChannelTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row." DEFVAL { nonVolatile } ::= { lmpControlChannelEntry 22 } -- End of lmpControlChannelTable -- LMP Control Channel Performance Table lmpControlChannelPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpControlChannelPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies LMP control channel performance counters." ::= { lmpObjects 11 } lmpControlChannelPerfEntry OBJECT-TYPE SYNTAX LmpControlChannelPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by a LMP-enabled device for every control channel. lmpCcCounterDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table." INDEX { lmpCcId } ::= { lmpControlChannelPerfTable 1 } LmpControlChannelPerfEntry ::= SEQUENCE { lmpCcInOctets Counter32, lmpCcInDiscards Counter32, lmpCcInErrors Counter32, lmpCcOutOctets Counter32, lmpCcOutDiscards Counter32, lmpCcOutErrors Counter32, Dubuc, et al. Standards Track [Page 24]
RFC 4327 LMP-MIB Module January 2006 lmpCcConfigReceived Counter32, lmpCcConfigSent Counter32, lmpCcConfigRetransmit Counter32, lmpCcConfigAckReceived Counter32, lmpCcConfigAckSent Counter32, lmpCcConfigNackReceived Counter32, lmpCcConfigNackSent Counter32, lmpCcHelloReceived Counter32, lmpCcHelloSent Counter32, lmpCcBeginVerifyReceived Counter32, lmpCcBeginVerifySent Counter32, lmpCcBeginVerifyRetransmit Counter32, lmpCcBeginVerifyAckReceived Counter32, lmpCcBeginVerifyAckSent Counter32, lmpCcBeginVerifyNackReceived Counter32, lmpCcBeginVerifyNackSent Counter32, lmpCcEndVerifyReceived Counter32, lmpCcEndVerifySent Counter32, lmpCcEndVerifyRetransmit Counter32, lmpCcEndVerifyAckReceived Counter32, lmpCcEndVerifyAckSent Counter32, lmpCcTestStatusSuccessReceived Counter32, lmpCcTestStatusSuccessSent Counter32, lmpCcTestStatusSuccessRetransmit Counter32, lmpCcTestStatusFailureReceived Counter32, lmpCcTestStatusFailureSent Counter32, lmpCcTestStatusFailureRetransmit Counter32, lmpCcTestStatusAckReceived Counter32, lmpCcTestStatusAckSent Counter32, lmpCcLinkSummaryReceived Counter32, lmpCcLinkSummarySent Counter32, lmpCcLinkSummaryRetransmit Counter32, lmpCcLinkSummaryAckReceived Counter32, lmpCcLinkSummaryAckSent Counter32, lmpCcLinkSummaryNackReceived Counter32, lmpCcLinkSummaryNackSent Counter32, lmpCcChannelStatusReceived Counter32, lmpCcChannelStatusSent Counter32, lmpCcChannelStatusRetransmit Counter32, lmpCcChannelStatusAckReceived Counter32, lmpCcChannelStatusAckSent Counter32, lmpCcChannelStatusReqReceived Counter32, lmpCcChannelStatusReqSent Counter32, lmpCcChannelStatusReqRetransmit Counter32, lmpCcChannelStatusRspReceived Counter32, lmpCcChannelStatusRspSent Counter32, lmpCcCounterDiscontinuityTime TimeStamp } Dubuc, et al. Standards Track [Page 25]
RFC 4327 LMP-MIB Module January 2006 lmpCcInOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LMP message octets received on the control channel." ::= { lmpControlChannelPerfEntry 1 } lmpCcInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound packets that were chosen to be discarded even though no errors had been detected. One possible reason for discarding such a packet could be to free up buffer space." ::= { lmpControlChannelPerfEntry 2 } lmpCcInErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound packets that contained errors preventing them from being processed by LMP." ::= { lmpControlChannelPerfEntry 3 } lmpCcOutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LMP message octets transmitted out of the control channel." ::= { lmpControlChannelPerfEntry 4 } lmpCcOutDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound packets that were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." Dubuc, et al. Standards Track [Page 26]
RFC 4327 LMP-MIB Module January 2006 ::= { lmpControlChannelPerfEntry 5 } lmpCcOutErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound packets that could not be transmitted because of errors." ::= { lmpControlChannelPerfEntry 6 } lmpCcConfigReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Config messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 7 } lmpCcConfigSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Config messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 8 } lmpCcConfigRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Config messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 9 } lmpCcConfigAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ConfigAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 10 } lmpCcConfigAckSent OBJECT-TYPE Dubuc, et al. Standards Track [Page 27]
RFC 4327 LMP-MIB Module January 2006 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ConfigAck messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 11 } lmpCcConfigNackReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ConfigNack messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 12 } lmpCcConfigNackSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ConfigNack messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 13 } lmpCcHelloReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Hello messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 14 } lmpCcHelloSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Hello messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 15 } lmpCcBeginVerifyReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current Dubuc, et al. Standards Track [Page 28]
RFC 4327 LMP-MIB Module January 2006 DESCRIPTION "This object counts the number of BeginVerify messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 16 } lmpCcBeginVerifySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerify messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 17 } lmpCcBeginVerifyRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerify messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 18 } lmpCcBeginVerifyAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 19 } lmpCcBeginVerifyAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyAck messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 20 } lmpCcBeginVerifyNackReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyNack messages that have been received on this control channel." Dubuc, et al. Standards Track [Page 29]
RFC 4327 LMP-MIB Module January 2006 ::= { lmpControlChannelPerfEntry 21 } lmpCcBeginVerifyNackSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyNack messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 22 } lmpCcEndVerifyReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 23 } lmpCcEndVerifySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 24 } lmpCcEndVerifyRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 25 } lmpCcEndVerifyAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerifyAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 26 } lmpCcEndVerifyAckSent OBJECT-TYPE Dubuc, et al. Standards Track [Page 30]
RFC 4327 LMP-MIB Module January 2006 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerifyAck messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 27 } lmpCcTestStatusSuccessReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 28 } lmpCcTestStatusSuccessSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 29 } lmpCcTestStatusSuccessRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 30 } lmpCcTestStatusFailureReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusFailure messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 31 } lmpCcTestStatusFailureSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current Dubuc, et al. Standards Track [Page 31]
RFC 4327 LMP-MIB Module January 2006 DESCRIPTION "This object counts the number of TestStatusFailure messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 32 } lmpCcTestStatusFailureRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusFailure messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 33 } lmpCcTestStatusAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 34 } lmpCcTestStatusAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusAck messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 35 } lmpCcLinkSummaryReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 36 } lmpCcLinkSummarySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been sent on this control channel." Dubuc, et al. Standards Track [Page 32]
RFC 4327 LMP-MIB Module January 2006 ::= { lmpControlChannelPerfEntry 37 } lmpCcLinkSummaryRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been retransmitted over this control channel." ::= { lmpControlChannelPerfEntry 38 } lmpCcLinkSummaryAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 39 } lmpCcLinkSummaryAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryAck messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 40 } lmpCcLinkSummaryNackReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryNack messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 41 } lmpCcLinkSummaryNackSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryNack messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 42 } lmpCcChannelStatusReceived OBJECT-TYPE Dubuc, et al. Standards Track [Page 33]
RFC 4327 LMP-MIB Module January 2006 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 43 } lmpCcChannelStatusSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 44 } lmpCcChannelStatusRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been retransmitted on this control channel." ::= { lmpControlChannelPerfEntry 45 } lmpCcChannelStatusAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusAck messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 46 } lmpCcChannelStatusAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 47 } lmpCcChannelStatusReqReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current Dubuc, et al. Standards Track [Page 34]
RFC 4327 LMP-MIB Module January 2006 DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 48 } lmpCcChannelStatusReqSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 49 } lmpCcChannelStatusReqRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been retransmitted on this control channel." ::= { lmpControlChannelPerfEntry 50 } lmpCcChannelStatusRspReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusResponse messages that have been received on this control channel." ::= { lmpControlChannelPerfEntry 51 } lmpCcChannelStatusRspSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusResponse messages that have been sent on this control channel." ::= { lmpControlChannelPerfEntry 52 } lmpCcCounterDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime on the most recent occasion at which any one or more of this control channel's counters suffered a Dubuc, et al. Standards Track [Page 35]
RFC 4327 LMP-MIB Module January 2006 discontinuity. The relevant counters are the specific instances associated with this control channel of any Counter32 object contained in the lmpControlChannelPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value." ::= { lmpControlChannelPerfEntry 53 } -- End of lmpControlChannelPerfTable -- LMP TE Link Table lmpTeLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpTeLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the LMP-specific TE link information. Overall TE link information is kept in three separate tables: ifTable for interface-specific information, lmpTeLinkTable for LMP specific information, and teLinkTable for generic TE link information. ifIndex is the common index to all tables." ::= { lmpObjects 12 } lmpTeLinkEntry OBJECT-TYPE SYNTAX LmpTeLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table exists for each ifEntry with an ifType of teLink(200) that is managed by LMP. An ifEntry with an ifIndex must exist before the corresponding lmpTeLinkEntry is created. If a TE link entry in the ifTable is destroyed, then so is the corresponding entry in the lmpTeLinkTable. The administrative status value is controlled from the ifEntry. Setting the administrative status to testing prompts LMP to start link verification on the TE link. Information about the TE link that is not LMP specific is contained in teLinkTable of the TE-LINK-STD-MIB MIB module." INDEX { ifIndex } ::= { lmpTeLinkTable 1 } LmpTeLinkEntry ::= SEQUENCE { lmpTeLinkNbrRemoteNodeId LmpNodeId, lmpTeLinkVerification TruthValue, lmpTeLinkFaultManagement TruthValue, Dubuc, et al. Standards Track [Page 36]
RFC 4327 LMP-MIB Module January 2006 lmpTeLinkDwdm TruthValue, lmpTeLinkOperStatus INTEGER, lmpTeLinkRowStatus RowStatus, lmpTeLinkStorageType StorageType } lmpTeLinkNbrRemoteNodeId OBJECT-TYPE SYNTAX LmpNodeId MAX-ACCESS read-create STATUS current DESCRIPTION "This is the Node ID of the TE link remote node. This value may be learned during control channel parameter negotiation phase (in the Config message). Node ID is an address whose type must be IPv4." ::= { lmpTeLinkEntry 1 } lmpTeLinkVerification OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if the LMP link verification procedure is enabled for this TE link." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpTeLinkEntry 2 } lmpTeLinkFaultManagement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if the LMP fault management procedure is enabled on this TE link." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpTeLinkEntry 3 } lmpTeLinkDwdm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if the LMP DWDM procedure is enabled on this TE link." REFERENCE "Link Management Protocol (LMP) for Dense Wavelength Division Dubuc, et al. Standards Track [Page 37]
RFC 4327 LMP-MIB Module January 2006 Multiplexing (DWDM) Optical Line Systems, RFC 4209" ::= { lmpTeLinkEntry 4 } lmpTeLinkOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3), init(4), degraded(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of this TE link. The status is set to testing when the TE link is performing link verification. A degraded state indicates that there is no active control channel between the pair of nodes that form the endpoints of the TE link, but yet at least one data-bearing link on the TE link is allocated." ::= { lmpTeLinkEntry 5 } lmpTeLinkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated." ::= { lmpTeLinkEntry 6 } lmpTeLinkStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row in the lmpTeLinkTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row." DEFVAL { nonVolatile } ::= { lmpTeLinkEntry 7 } -- End of lmpTeLinkTable lmpGlobalLinkVerificationInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" Dubuc, et al. Standards Track [Page 38]
RFC 4327 LMP-MIB Module January 2006 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates how often the link verification procedure is executed. The interval is in milliseconds. A value of 0 is used to indicate that the link verification procedure should not be executed. The interval specified in this object should be large enough to allow the verification procedure to be completed before the start of the next interval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." ::= { lmpObjects 13 } -- LMP Link Verification Table lmpLinkVerificationTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpLinkVerificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies TE link information associated with the LMP verification procedure." ::= { lmpObjects 14 } lmpLinkVerificationEntry OBJECT-TYPE SYNTAX LmpLinkVerificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by an LMP-enabled device for every TE link that supports the LMP verification procedure." INDEX { ifIndex } ::= { lmpLinkVerificationTable 1 } LmpLinkVerificationEntry ::= SEQUENCE { lmpLinkVerifyInterval LmpInterval, lmpLinkVerifyDeadInterval LmpInterval, lmpLinkVerifyTransportMechanism BITS, lmpLinkVerifyAllLinks TruthValue, lmpLinkVerifyTransmissionRate Unsigned32, lmpLinkVerifyWavelength Unsigned32, lmpLinkVerifyRowStatus RowStatus, lmpLinkVerifyStorageType StorageType } Dubuc, et al. Standards Track [Page 39]
RFC 4327 LMP-MIB Module January 2006 lmpLinkVerifyInterval OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the VerifyInterval parameter used in the LMP link verification process. It indicates the interval at which the Test messages are sent." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpLinkVerificationEntry 1 } lmpLinkVerifyDeadInterval OBJECT-TYPE SYNTAX LmpInterval MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the VerifyDeadInterval parameter used in the verification of the physical connectivity of data- bearing links. It specifies the observation period used to detect a Test message at the remote node." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpLinkVerificationEntry 2 } lmpLinkVerifyTransportMechanism OBJECT-TYPE SYNTAX BITS { -- All encoding types: payload(0), -- SONET/SDH encoding type: dccSectionOverheadBytes(1), dccLineOverheadBytes(2), j0Trace(3), j1Trace(4), j2Trace(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This defines the transport mechanism for the Test messages. The scope of this bit mask is restricted to each link encoding type. The local node will set the bits corresponding to the various mechanisms it can support for transmitting LMP Test messages. The receiver chooses the appropriate mechanism in the BeginVerifyAck message." REFERENCE "Link Management Protocol, RFC 4204 Dubuc, et al. Standards Track [Page 40]
RFC 4327 LMP-MIB Module January 2006 Synchronous Optical Network (SONET)/Synchronous Digital Hierarchy (SDH) Encoding for Link Management Protocol (LMP) Test Messages, RFC 4207" ::= { lmpLinkVerificationEntry 3 } lmpLinkVerifyAllLinks OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "A value of true(2) for this object indicates that the verification process checks all unallocated links, otherwise only the new ports or component links that have been added to this TE link are verified." ::= { lmpLinkVerificationEntry 4 } lmpLinkVerifyTransmissionRate OBJECT-TYPE SYNTAX Unsigned32 UNITS "bytes per second" MAX-ACCESS read-create STATUS current DESCRIPTION "This is the transmission rate of the data link over which the Test messages will be transmitted and is expressed in bytes per second." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpLinkVerificationEntry 5 } lmpLinkVerifyWavelength OBJECT-TYPE SYNTAX Unsigned32 UNITS "nanometers" MAX-ACCESS read-create STATUS current DESCRIPTION "This value corresponds to the wavelength at which the Test messages will be transmitted and is measured in nanometers (nm). If each data-bearing link corresponds to a separate wavelength, then this value should be set to 0." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpLinkVerificationEntry 6 } lmpLinkVerifyRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current Dubuc, et al. Standards Track [Page 41]
RFC 4327 LMP-MIB Module January 2006 DESCRIPTION "This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated." ::= { lmpLinkVerificationEntry 7 } lmpLinkVerifyStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row in the lmpLinkVerificationTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row." DEFVAL { nonVolatile } ::= { lmpLinkVerificationEntry 8 } -- End of lmpLinkVerificationTable -- LMP TE Link Performance Table lmpTeLinkPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpTeLinkPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies LMP TE link performance counters." ::= { lmpObjects 15 } lmpTeLinkPerfEntry OBJECT-TYPE SYNTAX LmpTeLinkPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by an LMP-enabled device for every TE link. lmpTeCounterDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table." INDEX { ifIndex } ::= { lmpTeLinkPerfTable 1 } LmpTeLinkPerfEntry ::= SEQUENCE { lmpTeInOctets Counter32, lmpTeOutOctets Counter32, Dubuc, et al. Standards Track [Page 42]
RFC 4327 LMP-MIB Module January 2006 lmpTeBeginVerifyReceived Counter32, lmpTeBeginVerifySent Counter32, lmpTeBeginVerifyRetransmit Counter32, lmpTeBeginVerifyAckReceived Counter32, lmpTeBeginVerifyAckSent Counter32, lmpTeBeginVerifyNackReceived Counter32, lmpTeBeginVerifyNackSent Counter32, lmpTeEndVerifyReceived Counter32, lmpTeEndVerifySent Counter32, lmpTeEndVerifyRetransmit Counter32, lmpTeEndVerifyAckReceived Counter32, lmpTeEndVerifyAckSent Counter32, lmpTeTestStatusSuccessReceived Counter32, lmpTeTestStatusSuccessSent Counter32, lmpTeTestStatusSuccessRetransmit Counter32, lmpTeTestStatusFailureReceived Counter32, lmpTeTestStatusFailureSent Counter32, lmpTeTestStatusFailureRetransmit Counter32, lmpTeTestStatusAckReceived Counter32, lmpTeTestStatusAckSent Counter32, lmpTeLinkSummaryReceived Counter32, lmpTeLinkSummarySent Counter32, lmpTeLinkSummaryRetransmit Counter32, lmpTeLinkSummaryAckReceived Counter32, lmpTeLinkSummaryAckSent Counter32, lmpTeLinkSummaryNackReceived Counter32, lmpTeLinkSummaryNackSent Counter32, lmpTeChannelStatusReceived Counter32, lmpTeChannelStatusSent Counter32, lmpTeChannelStatusRetransmit Counter32, lmpTeChannelStatusAckReceived Counter32, lmpTeChannelStatusAckSent Counter32, lmpTeChannelStatusReqReceived Counter32, lmpTeChannelStatusReqSent Counter32, lmpTeChannelStatusReqRetransmit Counter32, lmpTeChannelStatusRspReceived Counter32, lmpTeChannelStatusRspSent Counter32, lmpTeCounterDiscontinuityTime TimeStamp } lmpTeInOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LMP message octets received for this TE link." ::= { lmpTeLinkPerfEntry 1 } Dubuc, et al. Standards Track [Page 43]
RFC 4327 LMP-MIB Module January 2006 lmpTeOutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LMP message octets transmitted out for this TE link." ::= { lmpTeLinkPerfEntry 2 } lmpTeBeginVerifyReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerify messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 3 } lmpTeBeginVerifySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerify messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 4 } lmpTeBeginVerifyRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerify messages that have been retransmitted for this TE link." ::= { lmpTeLinkPerfEntry 5 } lmpTeBeginVerifyAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyAck messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 6 } lmpTeBeginVerifyAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only Dubuc, et al. Standards Track [Page 44]
RFC 4327 LMP-MIB Module January 2006 STATUS current DESCRIPTION "This object counts the number of BeginVerifyAck messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 7 } lmpTeBeginVerifyNackReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyNack messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 8 } lmpTeBeginVerifyNackSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of BeginVerifyNack messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 9 } lmpTeEndVerifyReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 10 } lmpTeEndVerifySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 11 } lmpTeEndVerifyRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerify messages that Dubuc, et al. Standards Track [Page 45]
RFC 4327 LMP-MIB Module January 2006 have been retransmitted over this control channel." ::= { lmpTeLinkPerfEntry 12 } lmpTeEndVerifyAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerifyAck messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 13 } lmpTeEndVerifyAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of EndVerifyAck messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 14 } lmpTeTestStatusSuccessReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 15 } lmpTeTestStatusSuccessSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 16 } lmpTeTestStatusSuccessRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusSuccess messages that have been retransmitted for this TE link." ::= { lmpTeLinkPerfEntry 17 } Dubuc, et al. Standards Track [Page 46]
RFC 4327 LMP-MIB Module January 2006 lmpTeTestStatusFailureReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusFailure messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 18 } lmpTeTestStatusFailureSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusFailure messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 19 } lmpTeTestStatusFailureRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusFailure messages that have been retransmitted on this TE link." ::= { lmpTeLinkPerfEntry 20 } lmpTeTestStatusAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusAck messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 21 } lmpTeTestStatusAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of TestStatusAck messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 22 } lmpTeLinkSummaryReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only Dubuc, et al. Standards Track [Page 47]
RFC 4327 LMP-MIB Module January 2006 STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 23 } lmpTeLinkSummarySent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 24 } lmpTeLinkSummaryRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummary messages that have been retransmitted over this control channel." ::= { lmpTeLinkPerfEntry 25 } lmpTeLinkSummaryAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryAck messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 26 } lmpTeLinkSummaryAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryAck messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 27 } lmpTeLinkSummaryNackReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryNack messages that Dubuc, et al. Standards Track [Page 48]
RFC 4327 LMP-MIB Module January 2006 have been received for this TE link." ::= { lmpTeLinkPerfEntry 28 } lmpTeLinkSummaryNackSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of LinkSummaryNack messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 29 } lmpTeChannelStatusReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 30 } lmpTeChannelStatusSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 31 } lmpTeChannelStatusRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been retransmitted for this TE link." ::= { lmpTeLinkPerfEntry 32 } lmpTeChannelStatusAckReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusAck messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 33 } Dubuc, et al. Standards Track [Page 49]
RFC 4327 LMP-MIB Module January 2006 lmpTeChannelStatusAckSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatus messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 34 } lmpTeChannelStatusReqReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 35 } lmpTeChannelStatusReqSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 36 } lmpTeChannelStatusReqRetransmit OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusRequest messages that have been retransmitted for this TE link." ::= { lmpTeLinkPerfEntry 37 } lmpTeChannelStatusRspReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of ChannelStatusResponse messages that have been received for this TE link." ::= { lmpTeLinkPerfEntry 38 } lmpTeChannelStatusRspSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only Dubuc, et al. Standards Track [Page 50]
RFC 4327 LMP-MIB Module January 2006 STATUS current DESCRIPTION "This object counts the number of ChannelStatusResponse messages that have been sent for this TE link." ::= { lmpTeLinkPerfEntry 39 } lmpTeCounterDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime on the most recent occasion at which any one or more of this TE link's counters suffered a discontinuity. The relevant counters are the specific instances associated with this TE link of any Counter32 object contained in the lmpTeLinkPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value." ::= { lmpTeLinkPerfEntry 40 } -- End of lmpTeLinkPerfTable -- LMP Data Link Table lmpDataLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpDataLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the data-bearing links managed by the LMP." ::= { lmpObjects 16 } lmpDataLinkEntry OBJECT-TYPE SYNTAX LmpDataLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table exists for each ifEntry that represents a data-bearing link. An ifEntry with an ifIndex must exist before the corresponding lmpDataLinkEntry is created. If an entry representing the data-bearing link is destroyed in the ifTable, then so is the corresponding entry in the lmpDataLinkTable. The administrative status value is controlled from the ifEntry. The index to this table is also used to get information in the componentLinkTable Dubuc, et al. Standards Track [Page 51]
RFC 4327 LMP-MIB Module January 2006 of the TE-LINK-STD-MIB MIB module." INDEX { ifIndex } ::= { lmpDataLinkTable 1 } LmpDataLinkEntry ::= SEQUENCE { lmpDataLinkType INTEGER, lmpDataLinkAddressType InetAddressType, lmpDataLinkIpAddr InetAddress, lmpDataLinkRemoteIpAddress InetAddress, lmpDataLinkRemoteIfId InterfaceIndexOrZero, lmpDataLinkEncodingType TeLinkEncodingType, lmpDataLinkActiveOperStatus INTEGER, lmpDataLinkPassiveOperStatus INTEGER, lmpDataLinkRowStatus RowStatus, lmpDataLinkStorageType StorageType } lmpDataLinkType OBJECT-TYPE SYNTAX INTEGER { port(1), componentLink(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies whether this data-bearing link is a port or a component link. Component link are multiplex capable, whereas ports are not multiplex capable." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpDataLinkEntry 1 } lmpDataLinkAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute specifies the data-bearing link IP address type. If the data-bearing link is unnumbered, the address type must be set to unknown(0)." ::= { lmpDataLinkEntry 2 } lmpDataLinkIpAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The local Internet address for numbered links. The type Dubuc, et al. Standards Track [Page 52]
RFC 4327 LMP-MIB Module January 2006 of this address is determined by the value of lmpDataLinkAddressType object. For IPv4 and IPv6 numbered links, this object represents the local IP address associated with the data-bearing link. For an unnumbered link, the local address is of type unknown and this object is set to the zero-length string and the ifIndex object then identifies the unnumbered address." ::= { lmpDataLinkEntry 3 } lmpDataLinkRemoteIpAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The remote Internet address for numbered data-bearing links. The type of this address is determined by the lmpDataLinkAddressType object. For IPv4 and IPv6 numbered links, this object represents the remote IP address associated with the data-bearing link. For an unnumbered link, the remote address is of type unknown and this object is set to the zero-length string and the lmpDataLinkRemoteIfId object then identifies the unnumbered address. This information is either configured manually or communicated by the remote node during the link verification procedure." ::= { lmpDataLinkEntry 4 } lmpDataLinkRemoteIfId OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "Interface identifier of the remote end point. This information is either configured manually or communicated by the remote node during the link verification procedure." ::= { lmpDataLinkEntry 5 } lmpDataLinkEncodingType OBJECT-TYPE SYNTAX TeLinkEncodingType MAX-ACCESS read-create STATUS current DESCRIPTION Dubuc, et al. Standards Track [Page 53]
RFC 4327 LMP-MIB Module January 2006 "The encoding type of the data-bearing link." REFERENCE "Generalized MPLS Signaling Functional Description, RFC 3471" ::= { lmpDataLinkEntry 6 } lmpDataLinkActiveOperStatus OBJECT-TYPE SYNTAX INTEGER { upAlloc(1), upFree(2), down(3), testing(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of this data-bearing link (active FSM)." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpDataLinkEntry 7 } lmpDataLinkPassiveOperStatus OBJECT-TYPE SYNTAX INTEGER { upAlloc(1), upFree(2), down(3), psvTst(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual operational status of this data-bearing link (passive FSM)." REFERENCE "Link Management Protocol, RFC 4204" ::= { lmpDataLinkEntry 8 } lmpDataLinkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated." ::= { lmpDataLinkEntry 9 } lmpDataLinkStorageType OBJECT-TYPE Dubuc, et al. Standards Track [Page 54]
RFC 4327 LMP-MIB Module January 2006 SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row in the lmpDataLinkTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row." DEFVAL { nonVolatile } ::= { lmpDataLinkEntry 10 } -- End of lmpDataLinkTable -- LMP Data Link Performance Table lmpDataLinkPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF LmpDataLinkPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the data-bearing links LMP performance counters." ::= { lmpObjects 17 } lmpDataLinkPerfEntry OBJECT-TYPE SYNTAX LmpDataLinkPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table contains information about the LMP performance counters for the data-bearing links. lmpDataLinkDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table." INDEX { ifIndex } ::= { lmpDataLinkPerfTable 1 } LmpDataLinkPerfEntry ::= SEQUENCE { lmpDataLinkTestReceived Counter32, lmpDataLinkTestSent Counter32, lmpDataLinkActiveTestSuccess Counter32, lmpDataLinkActiveTestFailure Counter32, lmpDataLinkPassiveTestSuccess Counter32, lmpDataLinkPassiveTestFailure Counter32, lmpDataLinkDiscontinuityTime TimeStamp } lmpDataLinkTestReceived OBJECT-TYPE Dubuc, et al. Standards Track [Page 55]
RFC 4327 LMP-MIB Module January 2006 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Test messages that have been received on this data-bearing link." ::= { lmpDataLinkPerfEntry 1 } lmpDataLinkTestSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Test messages that have been sent on this data-bearing link." ::= { lmpDataLinkPerfEntry 2 } lmpDataLinkActiveTestSuccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of data-bearing link tests that were successful on the active side of this data- bearing link." ::= { lmpDataLinkPerfEntry 3 } lmpDataLinkActiveTestFailure OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of data-bearing link tests that failed on the active side of this data-bearing link." ::= { lmpDataLinkPerfEntry 4 } lmpDataLinkPassiveTestSuccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of data-bearing link tests that were successful on the passive side of this data- bearing link." ::= { lmpDataLinkPerfEntry 5 } lmpDataLinkPassiveTestFailure OBJECT-TYPE SYNTAX Counter32 Dubuc, et al. Standards Track [Page 56]
RFC 4327 LMP-MIB Module January 2006 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of data-bearing link tests that failed on the passive side of this data-bearing link." ::= { lmpDataLinkPerfEntry 6 } lmpDataLinkDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime on the most recent occasion at which any one or more of this data-bearing link's counters suffered a discontinuity. The relevant counters are the specific instances associated with this data-bearing link of any Counter32 object contained in the lmpDataLinkPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value." ::= { lmpDataLinkPerfEntry 7 } -- End of lmpDataLinkPerfTable -- Notification Configuration lmpNotificationMaxRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The LMP notification rate depends on the size of the network, the type of links, the network configuration, the reliability of the network, etc. When designing this MIB, care has been taken to minimize the amount of notifications generated for LMP purposes. Wherever possible, notifications are state driven, meaning the notifications are sent only when the system changes state. The only notifications that are repeated and could cause a problem as far as congestion is concerned are the ones associated with data link verification. Without any considerations to handling of these notifications, a problem may arise if the number of data links is high. Since the data link verification notifications can happen only once per data link per link verification interval, the notification rate should be sustainable if one Dubuc, et al. Standards Track [Page 57]
RFC 4327 LMP-MIB Module January 2006 chooses an appropriate link verification interval for a given network configuration. For instance, a network of 100 nodes with 5 links of 128 wavelengths each and a link verification of 1 minute with no more than 10% of the links failed at any given time would have 1 notification per second sent from each node, or 100 notifications per second for the whole network. The rest of the notifications are negligible compared to this number. To alleviate the congestion problem, the lmpNotificationMaxRate object can be used to implement a throttling mechanism. It is also possible to enable/disable certain type of notifications. This variable indicates the maximum number of notifications issued per minute. If events occur more rapidly, the implementation may simply fail to emit these notifications during that period, or may queue them until an appropriate time. A value of 0 means no throttling is applied and events may be notified at the rate at which they occur. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." ::= { lmpObjects 18 } lmpLinkPropertyNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of lmpTeLinkPropertyMismatch and lmpDataLinkPropertyMismatch notifications, otherwise these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." DEFVAL { false } ::= { lmpObjects 19 } lmpUnprotectedNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of lmpUnprotected notifications, otherwise these notifications are not emitted. Implementations should save the value of this object in Dubuc, et al. Standards Track [Page 58]
RFC 4327 LMP-MIB Module January 2006 persistent memory so that it survives restarts or reboot." DEFVAL { false } ::= { lmpObjects 20 } lmpCcUpDownNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of lmpControlChannelUp and lmpControlChannelDown notifications, otherwise these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." DEFVAL { false } ::= { lmpObjects 21 } lmpTeLinkNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of lmpTeLinkDegraded and lmpTeLinkNotDegraded notifications, otherwise these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." DEFVAL { false } ::= { lmpObjects 22 } lmpDataLinkNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If this object is true, then it enables the generation of lmpDataLinkVerificationFailure notification, otherwise these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot." DEFVAL { false } ::= { lmpObjects 23 } -- Notifications -- Link Property Mismatch Notifications Dubuc, et al. Standards Track [Page 59]
RFC 4327 LMP-MIB Module January 2006 lmpTeLinkPropertyMismatch NOTIFICATION-TYPE OBJECTS { teLinkRemoteIpAddr, teLinkIncomingIfId } STATUS current DESCRIPTION "This notification is generated when a TE link property mismatch is detected on the node. The received remote TE link ID of the misconfigured TE link is represented by either teLinkRemoteIpAddr or teLinkIncomingIfId depending on whether the TE link is numbered or unnumbered. This notification should not be sent unless lmpLinkPropertyNotificationsEnabled is true. It is recommended that this notification be reported only the first time a mismatch is detected. Otherwise, for a given TE link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval)." ::= { lmpNotifications 1 } lmpDataLinkPropertyMismatch NOTIFICATION-TYPE OBJECTS { lmpDataLinkType, lmpDataLinkRemoteIfId } STATUS current DESCRIPTION "This notification is generated when a data-bearing link property mismatch is detected on the node. lmpDataLinkType is used to identify the local identifiers associated with the data link (the data link interface index can be used to determine the TE link interface index as this relationship is captured in the interface stack table). The remote entity interface ID is the remote entity interface ID received in the LinkSummary message. This notification should not be sent unless lmpLinkPropertyNotificationsEnabled is true. It is recommended that this notification be reported only the first time a mismatch is detected. Otherwise, for a given data link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval)." ::= { lmpNotifications 2 } -- Neighbor Notification lmpUnprotected NOTIFICATION-TYPE OBJECTS { lmpCcNbrNodeId } STATUS current DESCRIPTION "This notification is generated when there are more than one control channels between LMP neighbors and the last redundant control channel has failed. If the remaining operational control channel fails, then there will be no more control channels between the pair of nodes and all the TE links Dubuc, et al. Standards Track [Page 60]
RFC 4327 LMP-MIB Module January 2006 between the pair of nodes will go to degraded state. This notification should not be sent unless lmpUnprotectedNotificationsEnabled is set to true." ::= { lmpNotifications 3 } -- Control Channel Notifications lmpControlChannelUp NOTIFICATION-TYPE OBJECTS { lmpCcAdminStatus, lmpCcOperStatus } STATUS current DESCRIPTION "This notification is generated when a control channel transitions to the up operational state. This notification should not be sent unless lmpCcUpDownNotificationsEnabled is true." ::= { lmpNotifications 4 } lmpControlChannelDown NOTIFICATION-TYPE OBJECTS { lmpCcAdminStatus, lmpCcOperStatus } STATUS current DESCRIPTION "This notification is generated when a control channel transitions out of the up operational state. This notification should not be sent unless lmpCcUpDownNotificationsEnabled is true." ::= { lmpNotifications 5 } -- TE Link Notification lmpTeLinkDegraded NOTIFICATION-TYPE OBJECTS { lmpTeLinkOperStatus } STATUS current DESCRIPTION "This notification is generated when a lmpTeLinkOperStatus object for a TE link enters the degraded state. This notification should not be sent unless lmpTeLinkNotificationsEnabled is true." ::= { lmpNotifications 6 } lmpTeLinkNotDegraded NOTIFICATION-TYPE OBJECTS { lmpTeLinkOperStatus } STATUS current DESCRIPTION "This notification is generated when a lmpTeLinkOperStatus object for a TE link leaves the degraded state. This notification should not be sent unless lmpTeLinkNotificationsEnabled is true." ::= { lmpNotifications 7 } Dubuc, et al. Standards Track [Page 61]
RFC 4327 LMP-MIB Module January 2006 -- Data-bearing Link Notification lmpDataLinkVerificationFailure NOTIFICATION-TYPE OBJECTS { lmpDataLinkActiveOperStatus, lmpDataLinkPassiveOperStatus } STATUS current DESCRIPTION "This notification is generated when a data-bearing link verification fails. This notification should not be sent unless lmpDataLinkNotificationsEnabled is true. For a given data link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval)." ::= { lmpNotifications 8 } -- End of notifications -- Module compliance lmpCompliances OBJECT IDENTIFIER ::= { lmpConformance 1 } lmpGroups OBJECT IDENTIFIER ::= { lmpConformance 2 } lmpModuleFullCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for agents that support the configuration and monitoring of LMP MIB." MODULE -- this module MANDATORY-GROUPS { lmpNodeGroup, lmpControlChannelGroup, lmpLinkPropertyCorrelationGroup, lmpPerfGroup, lmpTeLinkGroup, lmpDataLinkGroup } GROUP lmpCcIsNotInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are not interfaces, in addition to lmpControlChannelGroup. The following constraints apply: lmpCcIsIf must at least be read-only returning false(1)." GROUP lmpCcIsInterfaceGroup DESCRIPTION Dubuc, et al. Standards Track [Page 62]
RFC 4327 LMP-MIB Module January 2006 "This group is mandatory for devices that support control channels that are interfaces, in addition to lmpControlChannelGroup. The following constraints apply: lmpCcIsIf must at least be read-only returning true(2)." GROUP lmpLinkVerificationGroup DESCRIPTION "This group is mandatory for devices that support the link verification procedure." GROUP lmpNotificationGroup DESCRIPTION "This group is optional." -- lmpNbrTable OBJECT lmpNbrRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for notReady(3) and createAndWait(5) is not required." -- lmpControlChannelTable OBJECT lmpCcRemoteAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for non-point-to-point configurations." OBJECT lmpCcRemoteIpAddr SYNTAX InetAddress (SIZE(0|4|16)) DESCRIPTION "The size of the IP address depends on the address type." OBJECT lmpCcRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for notReady(3) and createAndWait(5) is not required." OBJECT lmpCcOperStatus SYNTAX INTEGER { up(1), down(2) } DESCRIPTION Dubuc, et al. Standards Track [Page 63]
RFC 4327 LMP-MIB Module January 2006 "A value of configSnd(3), configRcv(4), active(5), goingDown(6) need not be supported." -- lmpTeLinkTable OBJECT lmpTeLinkOperStatus SYNTAX INTEGER { up(1), down(2), degraded(5) } DESCRIPTION "The testing(3) and init(4) state need not be supported." OBJECT lmpTeLinkRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for notReady(3) and createAndWait(5) is not required." -- lmpDataLinkTable OBJECT lmpDataLinkActiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of testing(4) need not be supported." OBJECT lmpDataLinkPassiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of psvTst(4) need not be supported." OBJECT lmpDataLinkRowStatus SYNTAX RowStatus { active(1), notInService(2) } WRITE-SYNTAX RowStatus { active(1), notInService(2), createAndGo(4), destroy(6) } DESCRIPTION "Support for notReady(3) and createAndWait(5) is not required." ::= { lmpCompliances 1 } lmpModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for agents that support the monitoring of the LMP MIB." MODULE -- this module -- The mandatory groups have to be implemented Dubuc, et al. Standards Track [Page 64]
RFC 4327 LMP-MIB Module January 2006 -- by all LMP-enabled devices. However, they may all be supported -- as read-only objects in the case where manual -- configuration is not supported. MANDATORY-GROUPS { lmpNodeGroup, lmpControlChannelGroup, lmpLinkPropertyCorrelationGroup, lmpPerfGroup, lmpTeLinkGroup, lmpDataLinkGroup } GROUP lmpCcIsNotInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are not interfaces, in addition to lmpControlChannelGroup. The following constraints apply: lmpCcIsIf must at least be read-only returning false(1)." GROUP lmpCcIsInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are interfaces, in addition to lmpControlChannelGroup. The following constraints apply: lmpCcIsIf must at least be read-only returning true(2)." GROUP lmpLinkVerificationGroup DESCRIPTION "This group is mandatory for devices that support the link verification procedure." GROUP lmpNotificationGroup DESCRIPTION "This group is optional." -- Scalars OBJECT lmpAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpGlobalLinkVerificationInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefault MIN-ACCESS read-only Dubuc, et al. Standards Track [Page 65]
RFC 4327 LMP-MIB Module January 2006 DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefault MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNotificationMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpNbrTable OBJECT lmpNbrRetransmitInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetryLimit MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetransmitDelta MIN-ACCESS read-only DESCRIPTION Dubuc, et al. Standards Track [Page 66]
RFC 4327 LMP-MIB Module January 2006 "Write access is not required." OBJECT lmpNbrRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpNbrStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpControlChannelTable OBJECT lmpCcUnderlyingIfIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcIsIf MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcNbrNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRemoteAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for non-point-to-point configurations." OBJECT lmpCcRemoteIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "The size of the IP address depends on the address type." OBJECT lmpCcSetupRole MIN-ACCESS read-only DESCRIPTION "Write access is not required." Dubuc, et al. Standards Track [Page 67]
RFC 4327 LMP-MIB Module January 2006 OBJECT lmpCcAuthentication MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpCcOperStatus SYNTAX INTEGER { up(1), down(2) } DESCRIPTION "A value of configSnd(3), configRcv(4), active(5), goingDown(6) need not be supported." OBJECT lmpCcStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpLinkVerificationTable OBJECT lmpLinkVerifyInterval MIN-ACCESS read-only DESCRIPTION Dubuc, et al. Standards Track [Page 68]
RFC 4327 LMP-MIB Module January 2006 "Write access is not required." OBJECT lmpLinkVerifyDeadInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyAllLinks MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpTeLinkTable OBJECT lmpTeLinkNbrRemoteNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpTeLinkVerification MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkFaultManagement MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkDwdm MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkOperStatus SYNTAX INTEGER { up(1), down(2), degraded(5) } DESCRIPTION "The testing(3) and init(4) state need not be supported." OBJECT lmpTeLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpTeLinkStorageType Dubuc, et al. Standards Track [Page 69]
RFC 4327 LMP-MIB Module January 2006 MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpTeLinkVerificationTable OBJECT lmpLinkVerifyTransmissionRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyWavelength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpLinkVerifyStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." -- lmpDataLinkTable OBJECT lmpDataLinkAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for numbered links. For unnumbered links, the unknown(0) address type needs to be supported." OBJECT lmpDataLinkIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Size of data-bearing link IP address depends on type of data-bearing link. Data-bearing link IP address size is zero if link is unnumbered, four if link IP address is IPv4, and sixteen if link IP address is IPv6." OBJECT lmpDataLinkRemoteIpAddress Dubuc, et al. Standards Track [Page 70]
RFC 4327 LMP-MIB Module January 2006 SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkRemoteIfId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkEncodingType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpDataLinkActiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of testing(4) need not be supported." OBJECT lmpDataLinkPassiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of psvTst(4) need not be supported." OBJECT lmpDataLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpDataLinkStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { lmpCompliances 2 } -- Units of conformance lmpNodeGroup OBJECT-GROUP OBJECTS { lmpAdminStatus, lmpOperStatus, lmpNbrAdminStatus, lmpNbrOperStatus, Dubuc, et al. Standards Track [Page 71]
RFC 4327 LMP-MIB Module January 2006 lmpNbrRowStatus, lmpNbrStorageType, lmpUnprotectedNotificationsEnabled, lmpNotificationMaxRate } STATUS current DESCRIPTION "Collection of objects that represent LMP node configuration." ::= { lmpGroups 1 } lmpControlChannelGroup OBJECT-GROUP OBJECTS { lmpNbrRetransmitInterval, lmpNbrRetryLimit, lmpNbrRetransmitDelta, lmpNbrAdminStatus, lmpNbrOperStatus, lmpNbrRowStatus, lmpNbrStorageType, lmpCcHelloIntervalDefault, lmpCcHelloIntervalDefaultMin, lmpCcHelloIntervalDefaultMax, lmpCcHelloDeadIntervalDefault, lmpCcHelloDeadIntervalDefaultMin, lmpCcHelloDeadIntervalDefaultMax, lmpCcNbrNodeId, lmpCcRemoteId, lmpCcRemoteAddressType, lmpCcRemoteIpAddr, lmpCcSetupRole, lmpCcAuthentication, lmpCcHelloInterval, lmpCcHelloIntervalMin, lmpCcHelloIntervalMax, lmpCcHelloIntervalNegotiated, lmpCcHelloDeadInterval, lmpCcHelloDeadIntervalMin, lmpCcHelloDeadIntervalMax, lmpCcHelloDeadIntervalNegotiated, lmpCcOperStatus, lmpCcRowStatus, lmpCcStorageType, lmpCcUpDownNotificationsEnabled } STATUS current DESCRIPTION "Objects that can be used to configure LMP interface." Dubuc, et al. Standards Track [Page 72]
RFC 4327 LMP-MIB Module January 2006 ::= { lmpGroups 2 } lmpCcIsInterfaceGroup OBJECT-GROUP OBJECTS { lmpCcIsIf } STATUS current DESCRIPTION "Objects that can be used to configure control channels that are interfaces." ::= { lmpGroups 3 } lmpCcIsNotInterfaceGroup OBJECT-GROUP OBJECTS { lmpCcUnderlyingIfIndex, lmpCcIsIf, lmpCcLastChange, lmpCcAdminStatus } STATUS current DESCRIPTION "Objects that can be used to configure control channels that are not interfaces." ::= { lmpGroups 4 } lmpLinkPropertyCorrelationGroup OBJECT-GROUP OBJECTS { lmpLinkPropertyNotificationsEnabled } STATUS current DESCRIPTION "Collection of objects used to configure the link property correlation procedure." ::= { lmpGroups 5 } lmpLinkVerificationGroup OBJECT-GROUP OBJECTS { lmpGlobalLinkVerificationInterval, lmpLinkVerifyInterval, lmpLinkVerifyDeadInterval, lmpLinkVerifyTransportMechanism, lmpLinkVerifyAllLinks, lmpLinkVerifyTransmissionRate, lmpLinkVerifyWavelength, lmpLinkVerifyRowStatus, lmpLinkVerifyStorageType, lmpDataLinkNotificationsEnabled } STATUS current DESCRIPTION "Collection of objects that represent the link verification procedure configuration." ::= { lmpGroups 6 } Dubuc, et al. Standards Track [Page 73]
RFC 4327 LMP-MIB Module January 2006 lmpPerfGroup OBJECT-GROUP OBJECTS { lmpCcInOctets, lmpCcInDiscards, lmpCcInErrors, lmpCcOutOctets, lmpCcOutDiscards, lmpCcOutErrors, lmpCcConfigReceived, lmpCcConfigSent, lmpCcConfigRetransmit, lmpCcConfigAckReceived, lmpCcConfigAckSent, lmpCcConfigNackSent, lmpCcConfigNackReceived, lmpCcHelloReceived, lmpCcHelloSent, lmpCcBeginVerifyReceived, lmpCcBeginVerifySent, lmpCcBeginVerifyRetransmit, lmpCcBeginVerifyAckReceived, lmpCcBeginVerifyAckSent, lmpCcBeginVerifyNackReceived, lmpCcBeginVerifyNackSent, lmpCcEndVerifyReceived, lmpCcEndVerifySent, lmpCcEndVerifyRetransmit, lmpCcEndVerifyAckReceived, lmpCcEndVerifyAckSent, lmpCcTestStatusSuccessReceived, lmpCcTestStatusSuccessSent, lmpCcTestStatusSuccessRetransmit, lmpCcTestStatusFailureReceived, lmpCcTestStatusFailureSent, lmpCcTestStatusFailureRetransmit, lmpCcTestStatusAckReceived, lmpCcTestStatusAckSent, lmpCcLinkSummaryReceived, lmpCcLinkSummarySent, lmpCcLinkSummaryRetransmit, lmpCcLinkSummaryAckReceived, lmpCcLinkSummaryAckSent, lmpCcLinkSummaryNackReceived, lmpCcLinkSummaryNackSent, lmpCcChannelStatusReceived, lmpCcChannelStatusSent, lmpCcChannelStatusRetransmit, lmpCcChannelStatusAckReceived, lmpCcChannelStatusAckSent, Dubuc, et al. Standards Track [Page 74]
RFC 4327 LMP-MIB Module January 2006 lmpCcChannelStatusReqReceived, lmpCcChannelStatusReqSent, lmpCcChannelStatusReqRetransmit, lmpCcChannelStatusRspReceived, lmpCcChannelStatusRspSent, lmpCcCounterDiscontinuityTime, lmpTeInOctets, lmpTeOutOctets, lmpTeBeginVerifyReceived, lmpTeBeginVerifySent, lmpTeBeginVerifyRetransmit, lmpTeBeginVerifyAckReceived, lmpTeBeginVerifyAckSent, lmpTeBeginVerifyNackReceived, lmpTeBeginVerifyNackSent, lmpTeEndVerifyReceived, lmpTeEndVerifySent, lmpTeEndVerifyRetransmit, lmpTeEndVerifyAckReceived, lmpTeEndVerifyAckSent, lmpTeTestStatusSuccessReceived, lmpTeTestStatusSuccessSent, lmpTeTestStatusSuccessRetransmit, lmpTeTestStatusFailureReceived, lmpTeTestStatusFailureSent, lmpTeTestStatusFailureRetransmit, lmpTeTestStatusAckReceived, lmpTeTestStatusAckSent, lmpTeLinkSummaryReceived, lmpTeLinkSummarySent, lmpTeLinkSummaryRetransmit, lmpTeLinkSummaryAckReceived, lmpTeLinkSummaryAckSent, lmpTeLinkSummaryNackReceived, lmpTeLinkSummaryNackSent, lmpTeChannelStatusReceived, lmpTeChannelStatusSent, lmpTeChannelStatusRetransmit, lmpTeChannelStatusAckReceived, lmpTeChannelStatusAckSent, lmpTeChannelStatusReqReceived, lmpTeChannelStatusReqSent, lmpTeChannelStatusReqRetransmit, lmpTeChannelStatusRspSent, lmpTeChannelStatusRspReceived, lmpTeCounterDiscontinuityTime, lmpDataLinkTestReceived, lmpDataLinkTestSent, Dubuc, et al. Standards Track [Page 75]
RFC 4327 LMP-MIB Module January 2006 lmpDataLinkActiveTestSuccess, lmpDataLinkActiveTestFailure, lmpDataLinkPassiveTestSuccess, lmpDataLinkPassiveTestFailure, lmpDataLinkDiscontinuityTime } STATUS current DESCRIPTION "Collection of objects used to provide performance information about LMP interfaces and data-bearing links." ::= { lmpGroups 7 } lmpTeLinkGroup OBJECT-GROUP OBJECTS { lmpTeLinkNbrRemoteNodeId, lmpTeLinkVerification, lmpTeLinkFaultManagement, lmpTeLinkDwdm, lmpTeLinkOperStatus, lmpTeLinkRowStatus, lmpTeLinkStorageType, lmpTeLinkNotificationsEnabled } STATUS current DESCRIPTION "Objects that can be used to configure TE links." ::= { lmpGroups 8 } lmpDataLinkGroup OBJECT-GROUP OBJECTS { lmpDataLinkType, lmpDataLinkAddressType, lmpDataLinkIpAddr, lmpDataLinkRemoteIpAddress, lmpDataLinkRemoteIfId, lmpDataLinkEncodingType, lmpDataLinkActiveOperStatus, lmpDataLinkPassiveOperStatus, lmpDataLinkRowStatus, lmpDataLinkStorageType } STATUS current DESCRIPTION "Collection of objects that represent data-bearing link configuration." ::= { lmpGroups 9 } lmpNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { lmpTeLinkPropertyMismatch, lmpDataLinkPropertyMismatch, Dubuc, et al. Standards Track [Page 76]
RFC 4327 LMP-MIB Module January 2006 lmpUnprotected, lmpControlChannelUp, lmpControlChannelDown, lmpTeLinkDegraded, lmpTeLinkNotDegraded, lmpDataLinkVerificationFailure } STATUS current DESCRIPTION "Set of notifications defined in this module." ::= { lmpGroups 10 } -- End of LMP-MIB END 10. Security Considerations There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. These are the tables and objects and their sensitivity/vulnerability: - Unauthorized changes to the lmpNbrTable, lmpControlChannelTable, lmpTeLinkTable, and lmpDataLinkTable may disrupt allocation of resources in the network. Some of the readable objects in this MIB module (i.e., objects with a MAX-ACCESS other than not-accessible) may be considered sensitive or vulnerable in some network environments. It is thus important to control even GET and/or NOTIFY access to these objects and possibly to even encrypt the values of these objects when sending them over the network via SNMP. These are the tables and objects and their sensitivity/vulnerability: - The lmpNbrTable exposes network provider's node IP addresses. - lmpControlChannelTable exposes network provider's control network. - lmpDataLinkTable exposes network provider's data network. SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. Dubuc, et al. Standards Track [Page 77]
RFC 4327 LMP-MIB Module January 2006 It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see [RFC3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy). Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. 11. Contributors Sudheer Dharanikota EMail: sudheer@ieee.org 12. Acknowledgements The general structure of this document has been modeled around the MPLS Label Switching Router (LSR) MIB [RFC3813]. The authors wish to thank Dmitry Ryumkin, Baktha Muralidharan and George Wang. 13. IANA Considerations Each of the following "IANA Considerations" subsections requested IANA for new assignments. New assignments can only be made via a Standards Action as specified in [RFC2434]. 13.1. IANA Considerations for lmp ifType The IANA has assigned 227 ifType for LMP interfaces. 13.2. IANA Considerations for LMP-MIB The IANA has assigned { transmission 227 } to the LMP-MIB module specified in this document. Dubuc, et al. Standards Track [Page 78]
RFC 4327 LMP-MIB Module January 2006 14. References 14.1. Normative References [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [RFC2434] Narten, T. and H. Alvestrand, "Guidelines for Writing an IANA Considerations Section in RFCs", BCP 26, RFC 2434, October 1998. [RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000. [RFC2914] Floyd, S., "Congestion Control Principles", BCP 41, RFC 2914, September 2000. [RFC3471] Berger, L., "Generalized Multi-Protocol Label Switching (GMPLS) Signaling Functional Description", RFC 3471, January 2003. [RFC4001] Daniele, M., Haberman, B., Routhier, S., and J. Schoenwaelder, "Textual Conventions for Internet Network Addresses", RFC 4001, February 2005. [RFC4204] Lang, J., "Link Management Protocol (LMP)", RFC 4204, October 2005. [RFC4207] Lang, J. and D. Papadimitriou, "Synchronous Optical Network (SONET)/Synchronous Digital Hierarchy (SDH) Encoding for Link Management Protocol (LMP) Test Messages", RFC 4207, October 2005. Dubuc, et al. Standards Track [Page 79]
RFC 4327 LMP-MIB Module January 2006 [RFC4209] Fredette, A., Ed. and J. Lang, Ed., "Link Management Protocol (LMP) for Dense Wavelength Division Multiplexing (DWDM) Optical Line Systems", RFC 4209, October 2005. [RFC4220] Dubuc, M., Nadeau, T., and J. Lang, "Traffic Engineering Link Management Information Base", RFC 4220, November 2005. 14.2. Informative References [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002. [RFC3813] Srinivasan, C., Viswanathan, A., and T. Nadeau, "Multiprotocol Label Switching (MPLS) Traffic Engineering (TE) Management Information Base (MIB)", RFC 3812, June 2004. Dubuc, et al. Standards Track [Page 80]
RFC 4327 LMP-MIB Module January 2006 Authors' Addresses Martin Dubuc EMail: dubuc.consulting@sympatico.ca Thomas D. Nadeau Cisco Systems, Inc. 1414 Massachusetts Ave. Boxborough, MA 01719 EMail: tnadeau@cisco.com Jonathan P. Lang Sonos, Inc. 223 E. De La Guerra St. Santa Barbara, CA 93101 EMail: jplang@ieee.org Evan McGinnis Hammerhead Systems 640 Clyde Court Mountain View, CA 94043 EMail: emcginnis@hammerheadsystems.com Dubuc, et al. Standards Track [Page 81]
RFC 4327 LMP-MIB Module January 2006 Full Copyright Statement Copyright (C) The Internet Society (2006). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf-ipr@ietf.org. Acknowledgement Funding for the RFC Editor function is provided by the IETF Administrative Support Activity (IASA). Dubuc, et al. Standards Track [Page 82]